It's been just over a year since Minnesota adopted a new state plumbing code. One of the most conspicuous and annoying changes that was made to the plumbing code was the requirement for hideous dishwasher air gaps. A dishwasher air gap is an egg-sized device that gets mounted above the sink to help prevent contaminated water from draining back into the dishwasher.

These devices have been around for a long time, but they were never required in single family homes in Minnesota. Our old plumbing code used to say "Domestic use dishwashers may discharge into a sink, or discharge to a sink tailpiece or food-waste grinder if the discharge drain line is fastened as high as possible under the countertop." That's no longer good enough, however. The new code that was adopted on January 23rd, 2016 says the following under section 807.4:

The nitty-gritty details of exactly how this is being enforced throughout Minnesota is up to the professional judgment of the plumbing inspectors for each municipality. From what I've heard, air gaps are typically being required at the time that sinks or dishwashers are installed or replaced.

Installation Problems

Because these air gaps are a fairly new requirement, we've come across a lot of air gap devices that aren't installed properly. To understand these defects, it's helpful to understand how these devices function. The crudely marked-up photo below shows how they work.

Air gaps have an 'in' and an 'out'. The water coming in on the right side of my drawing above is being forced by the dishwasher pump, but the water going out is simply draining through gravity. Because of this, it's important for the 'out' hose to be larger than the 'in', as shown in the installation diagram below.

We commonly find the two hoses sized the same, as shown below. This is an improper installation.

The problem with this is that the undersized hose won't handle all of the water flow when it's no longer under pressure, which will cause the water to discharge out of the air gap, which should not happen under normal conditions. Here's a quick video clip showing what that looks like.

The other installation error that we've come across has been improperly located air gaps. As you might guess from the video clip above, if anything goes wrong with the discharge hose, an air gap will spit out water. Air gaps should be located in places where that discharged water will go to the drain; not all over a countertop, and especially not underneath a countertop.

Are these air gaps here to stay?

I hope not, and I'm guessing not. Plumbers don't like them, inspectors don't like them, and homeowners hate them. The last building code requirement that we had in Minnesota that was this universally disliked by the public was the residential sprinkler thing. That lasted about six months. I'm hoping that something similar will happen with the requirement for dishwasher air gaps.

Oh, and for the record, dishwasher air gaps are definitely not something that we recommend installing during our home inspections. While dishwasher air gaps are technically required on new installations by code, we're not code-compliance inspectors. As home inspectors, we get to make recommendations on stuff that makes sense to us. These don't.

Author: Reuben Saltzman, Structure Tech Home Inspections